Customization: | Available |
---|---|
Application: | High-performance Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 120/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SANYU SY5000 3Ph 380V 1Ph 220V 50/60Hz Solar Pump Inverter with CE
SY5000 Series Economic Frequency Inverter
AC 1PH 220V 0.4~2.2kW
AC 3PH 380V 0.75~18.5kW
Main features
VFD Series Type
Input |
Rated Voltage, Frequency |
3-phase(4#sereis)380V;50/60HZ 1-phase(S2#series)220V;50/60HZ |
|||
Allowed Voltage Range |
3-phase(4#series)320V~460V 1-phase(S2#series)160V~260V |
||||
Output |
Voltage |
4#series; 0~460V S2#series; 0~260V |
|||
frequency |
Low frequency mode: 0~300HZ ; High frequency mode: 0~3000HZ |
||||
Overload Capacity |
G type: 110% for long-term, 150% for 1 min, 180% for 5s P type: 105% for long-term, 120% for 1 min, 150% for 1s |
||||
Control Mode |
V/F control, advanced V/F control, V/F separation control, electric current vector control |
||||
Control Character |
Frequency Setting Resolution |
Analog Input |
0.1% of maximum output frequency |
||
Digital Setting |
0.01 Hz |
||||
Frequency Precision |
Analog Input |
Within 0.2% of maximum output frequency |
|||
Digital Setting |
Within 0.01% of set output frequency |
||||
V/F Control |
V/F Curve (voltage frequency character) |
Reference frequency setting 5~600 Hz, multipoint V/F curve setting, or fixed curve of constant torque, low decreasing torque 1, low decreasing torque 2, square torque |
|||
Torque Compensation |
Manual setting: 0.0~30% of rated output Automatic compensation: according to output current and motor parameter |
||||
Automatic Current-limiting and Voltage-limiting |
During acceleration, deceleration or steady running, detect automatically the current and voltage of motor stator, and control it within bounds based on unique algorithm, minimize fault-trip chance |
||||
Senseless Vector Control |
Voltage Frequency Character |
Adjust pressure/frequency ratio according to motor parameter and unique algorithm |
|||
Torque Character |
Starting torque: 3.0 Hz 150% rated torque (VF control) 0.5 Hz 180% rated torque (SVC, FVC) 0.05 Hz 180% rated torque (VC) Operating speed precision in steady state: ≤±0.5% rated synchronous speed Torque response: ≤50ms VC, SVC, FVC ≤20ms |
||||
Motor Parameter Self-measurement |
Being able to detect parameter automatically under static state and dynamic state of motor, thus guarantee an optimum control. |
||||
Current and Voltage Restrain |
Current closed-loop control, free from current impact, perfect restrain function of overcurrent and overvoltage |
||||
Undervoltage Restrain during Running |
Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy |
||||
Typical function |
Multi-velocity and Traverse Operation |
16 segments programmable multi-velocity control, multiple operation mode. Traverse operation: preset frequency and center frequency adjustable, parameter memory and recovery after power cut. |
|||
PID Control RS485 Communication |
Built-in PID controller (able to preset frequency). Standard configuration RS485 communication function, multiple communication protocol for choice, synchronizing control function. |
||||
Frequency Setting |
Analog Input |
Direct voltage 0~10V, direct current 0~20mA (optional up limit and lower limit) |
|||
Digital Input |
Operation panel setting, RS485 port setting, UP/DW terminal control, or combined with analog input |
||||
Output Signal |
Digital output |
2 channel OC output and 2 channel relay output (TA1, TB1, TC1/TA2,TB2,TC2), up to 16 choices |
|||
Analog output |
2 channel analog signal output, output ranging within 0~20mA or 0~10V with flexibly setting, achievable output of physical quantities like set frequency, output frequency |
||||
Automatic Steady-voltage Operation |
Dynamic steady state, static steady state, and unsteady voltage for choices to obtain the steadiest operation |
||||
Acceleration and Deceleration Time Setting |
0.1s~3600min continuous setting, S type and linear type mode for choice |
||||
Brake |
Dynamic Braking |
Dynamic braking initial voltage, backlash voltage and dynamic braking continuous adjustable |
|||
DC Braking |
Halt DC braking initial frequency: 0.00~[F0.16] upper limit frequency Braking time: 0.0~100.0s; Braking current: 0.0%~150.0% of rated current |
||||
Flux Restraint |
0~100 0: invalid |
||||
Low Noise Running |
Carrier frequency 1.0kHz~16.0kHz continuous adjustable, minimize motor noise |
||||
Speed Tracking and Restart Function |
Smooth restart during operation, instantaneous stop and restart |
||||
Counter |
A built-in counter, facilitate system integration |
||||
Operation Function |
Upper limit and lower limit frequency setting, frequency hopping operation, reversal running restraint, slip frequency compensation, RS485 communication, frequency control of progressive increase and decrease, failure recovery automatically, etc. |
Applications
SY5000 series is V/F & Vector control economical type which widely used in many fields, such as CNC machines,
water pump, textile machinery, printing machines, lift, crane and so on.