Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
Advanced control technologies include V/F control, advanced VF control, separate VF control, VF square curve control, without PG current vector control
Output frequency up to 999.9HZ
Stable operation and low price, it is a cost-effective and economical product.
Aluminum alloy heat dissipation, compact structure, saving installation space, suitable for various working conditions.
Torque compensation, multiple braking, undervoltage suppression, automatic current limiting and pressure limiting and other functions ensure safe and stable operation.
Standard RS485, MODBUS communication, detachable control panel, remote control
PID, counter, speed tracking and other special functions make the control more abundant.
Complete functions, widely used in fans, pumps and other occasions
Item | Description | |
Input | Rated voltage frequency | 380V or 220V:50HZ/60HZ |
Allowable voltage working range | Fluctuation range: ≤±20%; voltage unbalance rate: <3%; frequency: ±5% | |
Output | Rated voltage | 0~380V or 0 ~220V |
Frequency | 0~999.9HZ | |
Overload capacity | 150% rated current for 1 minute | |
Main control performance | Control model | V/F control, advanced VF control, separate VF control, VF square curve control, without PG current vector control |
Modulation | Space voltage vector PWM modulation | |
Speed range | 1: 100 (without PG vector control) | |
Starting torque | 150% rated torque at 3.0 Hz (Advanced VF control) | |
Speed stabilization accuracy | ≤±0.2% rated synchronous speed | |
Speed fluctuation | ≤±0.5% rated synchronous speed | |
Torque response | ≤50ms without PG vector control | |
Torque control | Support torque control without PG vector control mode Torque control accuracy:±5% |
|
Frequency accuracy | Digital setting: maximum frequency×±0.01%; Analog setting: maximum frequency×±0.2% |
|
Frequency resolution | Digital setting: 0.01Hz; Analog setting: maximum frequency×0.05% |
|
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
V/F curve | 6 control modes: 1 user setting V/F curve mode, 4 torque reduction characteristic curve modes (2.0 power, 1.7 power, 1.5 power, 1.3 power) and linear curve, square curve, multi-point VF curve | |
Acceleration and deceleration curve | Linear acceleration and deceleration. Time unit (minutes/second) optional, up to 999.9 seconds | |
DC braking | Starting frequency of DC braking at stop: 0.00-50.00HZ Braking time: 0.0-30.0S; braking current: 0.0%-50.0% rated current |
|
Automatic Voltage Adjustment (AVR) | When the grid voltage changes, it can automatically keep the output voltage constant | |
Automatic current limit | Automatically limit the current during operation to prevent frequent overcurrent fault tripping | |
Voltage stall | Control the voltage during deceleration to prevent overvoltage protection from stopping | |
Automatic carrier adjustment | Automatically adjust carrier frequency according to load characteristics and temperature characteristics; multiple carrier modes are optional | |
Customization function | Separate VF control | Easy to implement various power supply designs |
Textile swing frequency | Textile swing frequency control, can realize fixed swing frequency and variable swing frequency . | |
Frequency combination function | The running command channel and frequency reference channel can be combined arbitrarily | |
Jog | The jog forward rotation frequency can be set and the jog priority is enabled. The jog frequency range: 0.00Hz~50.00Hz; the jog acceleration and deceleration time can be set from 0.1 to 999.9s, and the jog interval time can be set from 0.1 to 999.9s . | |
Multi-speed operation | Achieve multi-speed operation through built-in PLC or control terminal | |
Built-in process closed-loop control | Can easily form a closed-loop control system. | |
Water supply burst detection | Burst detection delay time, high pressure detection threshold, low pressure detection threshold | |
Operation function | Run command channel | Operation panel. Bolt terminal, serial communication port, can be switched in various ways |
Frequency given channel | 2 kinds of digital setting, analog voltage setting, analog current setting, pulse setting, terminal setting, multi-speed setting, etc. | |
Auxiliary frequency setting | Achieve flexible auxiliary frequency fine-tuning and frequency synthesis | |
Pulse output terminal | 0~50kHz pulse square wave signal output, can realize the output of physical quantities such as set frequency and output frequency | |
Analog output terminal | 2 analog signal outputs. The output range is flexibly set between 0~20mA or 0~1OV, which can realize the output of physical quantities such as set frequency and output frequency | |
Operating Panel |
LED display | Can display 26 parameters such as set frequency, output frequency, output voltage, output current, etc. |
Key function selection | Define the action range of some keys to prevent misoperation | |
Protective function | Phase loss protection (optional), over-current protection, over-voltage protection, under-voltage protection, over-temperature protection. Overload protection, load loss protection, etc. | |
Environment | Location | Indoor. Free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping or salt etc. |
Altitude | Use derating above 1000 meters, derate 10% for every 1000 meters raised | |
Ambient temperature | -10C~+40C (If ambient temperature is 40C-50C, please use derating) | |
Humidity | 5%~95%RH, no condensation | |
Vibration | Less than 5.9m/s( 0.6g) | |
Storage temperature | -40C~+70C | |
Structure | Protection level | IP20 |
Cooling method | Air-cooled, with fan control | |
Efficiency | 7.5KW and below>93% | |
Model Selection
Input voltage | Model | Capacity | Input Current | Adapted motor |
(KVA) | (A) | (KW) | ||
220V 1-phase | SY2000-0R7G-S2 | 1.4 | 4 | 0.75 |
SY2000-1R5G-S2 | 2.6 | 7 | 1.5 | |
SY2000-2R2G-S2 | 3.8 | 10 | 2.2 | |
SY2000-004G-S2 | 8.8 | 16 | 4 | |
SY2000-5R5G-S2 | 11 | 22 | 5.5 | |
380V 3-phase | SY2000-0R7G-4 | 1.5 | 2.3 | 0.75 |
SY2000-1R5G-4 | 3.7 | 3.7 | 1.5 | |
SY2000-2R2G-4 | 4.7 | 5 | 2.2 | |
SY2000-004G/5R5P-4 | 5.9/8.9 | 10.5/14.6 | 4/5.5 | |
SY2000-5R5G/7R5P-4 | 8.9/11 | 14.6/20 | 5.5/7.5 | |
SY2000-7R5G/011P-4 | 11/15 | 20/27.5 | 7.5/11 | |
Dimension and Installation:
Wiring and Diagram:
Panel:
FAQ:
1.Q: Are you a factory or trading company?
A: We are trading company with our own factory with more than 10 assembly product line and strict QC system and equipment, so we can meet both your quantity and quality demands.
2.Q: Can I get some samples?
A: Yes,we are glad to offer you samples.After price and order confirmed, the samples fee will be regressed.
3.Q: When can I get the products?
A: You products will be arrived your the nearest domestic port after order confirmed, it's about 30 days.
4.Q: How does your factory do regarding quality control?
A: Our factory has gained SAA certificate and EMC certificate and ISO9002 authentication. Quality
makes us who we are today. We focus on the quality from the very beginning to the end.
5.Can I buy other factory's products directly from you?
A: Yes, of course. There are already many customers cooperating with us in this way. We have over 10 years .in the business with extensive knowledge of technology and market.Our good reputation in China has been awarded by Alibaba Group as its seleced business partner.